We provide Rental Services like Industrial Chamber Rental Services, Industrial Chambers on Rent, High Low Temperature & Humidity Chambers, High Low Temperature Chambers, 3 Zone Thermal Shock Chambers, Ovens, Industrial Ovens from Pune, Maharashtra, India.
| Make | WEISS TECHNIK |
| Work Space ( L*B*H ) MM | 500 X 800 X700 mm |
| Temperature Range | -60°C To +125°C |
| Rate of change of Temperature | Average 4°C/min Averaged from +125°C to -40°C. (Empty chamber) as per IEC 60068-3-5 measured at discharge of air. |
| Humidity Range | 30% to 98% ±3% in climatic range of +25°C to +85°C limited by min dew point of +4°C. |
| Temperature & Humidity Controller Programmer | Eurotherm 3504, Dual loop Self-tune microprocessor based PID temperature & humidity cyclic programmer |
| Power Requirement | 415 volts, ±5%, 3 phase Neutral, 50 Hz, AC power supply. |
| Mounting | Trolley Mounting Type with Caster Wheels. |
| No. of Chambers | 02 |
| Make | DRK TEST SOLUTIONS LLP. |
| Work Space (L*B*H ) MM | 700 X 700 X700 mm |
| Temperature Range | -60°C To +125°C |
| Rate of change of Temperature | Average 5°C/min Averaged from +125°C to -40°C. (Empty chamber) as per IEC 60068-3-5 measured at discharge of air. |
| Humidity Range | 30% to 98% ±3% in climatic range of +25°C to +85°C limited by min dew point of +4°C. |
| Temperature & Humidity Controller Programmer | Eurotherm 3504, Dual loop Self-tune microprocessor based PID temperature & humidity cyclic programmer |
| Power Requirement | 415 volts, ±5%, 3 phase Neutral, 50 Hz, AC power supply. |
| Mounting | Trolley Mounting Type with Caster Wheels. |
| No. of Chambers | 01 |
| Make | DRK TEST SOLUTIONS LLP. |
| Work Space ( L*B*H ) MM | 700 X 700 X700 mm |
| Temperature Range | -30°C To +125°C |
| Rate of change of Temperature | Average 1°C/min Averaged from +125°C to -30°C. (Empty chamber) as per IEC 60068-3-5 measured at discharge of air. |
| Humidity Range | N/A |
| Temperature Controller Programmer | Brainchild / Eurotherm, Single loop Self-tune microprocessor based PID temperature cyclic programmer |
| Power Requirement | 415 volts, ±5%, 3 phase Neutral, 50 Hz, AC power supply. |
| Mounting | Trolley Mounting Type with Caster Wheels. |
| No. of Chambers | 03 |
| Make | DRK TEST SOLUTIONS LLP. |
| Work Space ( L*B*H ) MM | 1000 X 1000 X1000 mm |
| Temperature Range | -60°C To +150°C |
| Rate of change of Temperature | Average 4°C/min Averaged from +125°C to -40°C. (Empty chamber) as per IEC 60068-3-5 measured at discharge of air. |
| Humidity Range | 30% to 98% ±3% in climatic range of +25°C to +85°C limited by min dew point of +4°C. |
| Temperature & Humidity Controller Programmer | Eurotherm 3504, Dual loop Self-tune microprocessor based PID temperature & humidity cyclic programmer |
| Power Requirement | 415 volts, ±5%, 3 phase Neutral, 50 Hz, AC power supply. |
| Mounting | Trolley Mounting Type with Caster Wheels. |
| No. of Chambers | 02 |
| Make | WEISS TECHNIK |
| Work Space (L*B*H ) MM | 500 X 600 X 400 mm (Basket Size) |
| Temperature Range | HOT Zone : +5°C Above Ambient To +150°C Ambient Zone : +50°C to 0°C COLD Zone : Up to -60°C |
| Thermal Shock Test Range | +150°C to -40°C. |
| Recovery Time | 10 Mins ± 3Mins |
| Temperature Controller & Programmer | PLC Based |
| Power Requirement | 415 volts, ±5%, 3 phase Neutral, 50 Hz, AC power supply. |
| Mounting | Trolley Mounting Type with Caster Wheels. |
| No. of Chambers | 01 |
| Make | DRK TEST SOLUTIONS LLP. |
| Work Space ( L*B*H ) MM | 550 X 600 X 1000 mm |
| Temperature Range | +5°C Above Ambient To +300°C |
| Temperature Controller & Programmer | Brainchild P91 (Programmable) |
| Power Requirement | 415 volts, ±5%, 3 phase Neutral, 50 Hz, AC power supply. |
| Mounting | Trolley Mounting Type with Caster Wheels. |
| No. of Chambers | 01 |
| Make | DRK TEST SOLUTIONS LLP. |
| Work Space (L*B*H ) MM | 2000 X 2000 X 2000 mm |
| Temperature Range | +5°C Above Ambient To +150°C |
| Temperature Controller & Programmer | Brainchild P91 (Programmable) |
| Power Requirement | 415 volts, ±5%, 3 phase Neutral, 50 Hz, AC power supply. |
| Mounting | Floor Mounting |
| No. of Chambers | 01 |